CIT3SX1R1G05KX (Order no. 096560)

Read/write head CIT3 G05 with serial interface

  • Serial interface RS232
  • Active face can be adjusted to 5 different positions
  • Standard housing according to EN 50041
  • Connection terminals
CIT3SX1R1G05KX (Order no. 096560)

Description

Serial interface

The individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652). For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Software Transponder Coding, see page 41).

Standard housing

The size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041. The division into 3 assemblies permits easy mounting and straightforward replacement.

Mounting instructions

On mounting the read/write head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read/write head is observed.

Attention:

On the use of a screened cable the connecting cable for the serial interface is allowed to be max. 5 m long.

Dimension drawing
Dimension drawing
Wiring diagram<br>Pin assignment table
Wiring diagram
Pin assignment table

Dimensional drawings

Dimensional drawings
1Active face
2Crossing direction
3LED status indication
4shield spring
mCenter offset
sRead distance

Connection examples

Connection examples

Accessories

Ordering data

Ordernumber 096560
Item designation CIT3SX1R1G05KX
Gross weight 0,372kg
Customs tariff number 85389099990
ECLASS 27-28-04-01 Identifikation, RFID Reader