CTP-L1-BR-M-HA-AE-SAB-168052 (Order no. 168052)

Transponder-coded safety switch CTP-AP, M12

  • Safety switch with guard locking and integrated evaluation electronics
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With plug connector M12
  • Multicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)
  • Test texts
  • Amendment
CTP-L1-BR-M-HA-AE-SAB-168052 (Order no. 168052)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Multicode evaluation

Every suitable actuator is detected by the switch.

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Guard locking type

CTP‑L1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IMPOperating voltage of guard locking solenoid, 24 V DCWH
2UBOperating voltage of AP electronics, 24 V DCBN
3FO1ASafety output, channel 1GN
4FO1BSafety output, channel 2YE
5OIDiagnostic outputGY
6ODDoor monitoring outputPK
70 V UBAP electronics operating voltage, 0 VBU
8IMMGuard locking solenoid operating voltage, 0 VRD
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw
3LEDs
4Plug connector aligned

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

FCC_2AJ58-13c_UL_us_E155795_3/11

Workspace

Repeat accuracy R 10 %

Operating and display elements

ItemColorExtrasNote slide-in labelSlide-in labelSwitching elementVersionNumberDesignation1LED
12 PDEmergency stop
21NOIlluminated pushbutton
31NOIlluminated pushbutton

Electrical connection values

Fuse
external (solenoid operating voltage IMP) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Power consumption 66667777777888888999999 W
Rated insulation voltage Ui 50 V
Rated impulse voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements 999999 /according to EN IEC 60947-5-3
Utilization category
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 270 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class III
Current consumption
IUB 40 mA
IIMP 400 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm)
Test pulse interval min. ca 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply
LED 24 V
Current consumption
LED 10 mA
Emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
Monitoring output OD/C
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
Safety outputs FO1A/FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 150 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Anfahrgeschwindigkeit max. 20 m/min
Connection type 2 plug connectors M12, 5- and 8-pin
Extraction force 20 N
Ready delay 5 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Storage temperature -25 ... 70 °C
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (In the inserted and screwed tight state)
Ambient temperature
at UB = 24 V DC -20 ... 55 °C
Material
Switch head cover Die-cast zinc
Safety switch housing Reinforced thermoplastic
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-5.38x10-9420 y


B10DMission time
Emergency stop0.13x10620 y


Miscellaneous

Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Additional feature incl. lens set, ID no. 120344

Accessories

Downloads

Single Documents

Doc. no.
Version
Language
Size
Doc. no. 2537376
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BR Unicode/Multicode V1.0.X up to V1.3.X and CTA-L1/2-BR Unicode/Multicode V1.0.X up to V2.1.X
Doc. no.
2537376
Version
03/23
Language
Size
5,3 MB
Doc. no. 2537376
Mode d’emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage CTP-L1/2-BR Uni-/multicode V1.0.X à la V1.3.X, CTA-L1/2-BR Uni-/multicode V1.0.X à la V2.1.X
Doc. no.
2537376
Version
03/23
Language
Size
5,3 MB
Doc. no. 2537376
Manual de instrucciones Interruptor de seguridad con codificación por transponder con bloqueo CTP-L1/2-BR Unicode/Multicode V1.0.X a la V1.3.X y CTA-L1/2-BR Unicode/Multicode V1.0.X a la V2.1.X
Doc. no.
2537376
Version
03/23
Language
Size
5,3 MB
Doc. no. 2537376
Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung CTP-L1/2-BR Uni-/Multicode V1.0.X bis V1.3.X und CTA-L1/2-BR Uni-/Multicode V1.0.X bis V2.1.X
Doc. no.
2537376
Version
03/23
Language
Size
5,3 MB
Doc. no. 2537376
Istruzioni di impiego Finecorsa di sicurezza con codifica a transponder con meccanismo di ritenuta CTP-L1/2-BR Unicode/Multicode V1.0.X alla V1.3.X, CTA-L1/2-BR Unicode/Multicode V1.0.X alla V2.1.X
Doc. no.
2537376
Version
03/23
Language
Size
5,3 MB
Doc. no. 2537376
操作説明書 トランスポンダー コーデッド安全スイッチ ガードロック付き CTP/CTA-L1/2-BR ユニコード/マルチコード V1.0.X から V1.3.X CTP/CTA-L1/2-BR ユニコード/マルチコード V1.0.X から V2.1.X
Doc. no.
2537376
Version
03/23
Language
Size
5,5 MB
Doc. no. 2537376
Návod k použití Bezpečnostní spínač s kódovaným transpondérem a jištěním ochranného krytu CTP-L1/2-BR Unicode/Multicode V1.0.X do V1.3.X, CTA-L1/2-BR Unicode/Multicode V1.0.X do V2.1.X
Doc. no.
2537376
Version
03/23
Language
Size
5,5 MB
Doc. no.
Version
Language
Size
Doc. no. MAN20001654
Operating Instructions Transponder-Coded Safety Switch with Guard Locking CTP-L1/2-BR Unicode/Multicode V1.4.X to V1.5.X, CTA-L1/2-BR Unicode/Multicode V2.2.X to V2.3.X
Doc. no.
MAN20001654
Version
04/24
Language
Size
6,0 MB
Doc. no. MAN20001654
Mode d’emploi Interrupteur de sécurité à codage par transpondeur avec interverrouillage CTP-L1/2-BR Uni-/multicode V1.4.X à V1.5.X, CTA-L1/2-BR Uni-/multicode V2.2.X à V2.3.X
Doc. no.
MAN20001654
Version
04/24
Language
Size
6,0 MB
Doc. no. MAN20001654
Manual de instrucciones Interruptor de seguridad codificado por transponder con bloqueo CTP-L1/2-BR Unicode/Multicode de V1.4.X a V1.5.X, CTA-L1/2-BR Unicode/Multicode de V2.2.X a V2.3.X
Doc. no.
MAN20001654
Version
04/24
Language
Size
6,0 MB
Doc. no. MAN20001654
Betriebsanleitung Transpondercodierter Sicherheitsschalter mit Zuhaltung CTP-L1/2-BR Uni-/Multicode V1.4.X bis V1.5.X, CTA-L1/2-BR Uni-/Multicode V2.2.X bis V2.3.X
Doc. no.
MAN20001654
Version
04/24
Language
Size
6,0 MB
Doc. no. MAN20001654
Istruzioni di impiego Finecorsa di sicurezza con codifica a transponder con meccanismo di ritenuta CTP-L1/2-BR Unicode/Multicode da V1.4.X a V1.5.X, CTA-L1/2-BR Unicode/Multicode da V2.2.X a V2.3.X
Doc. no.
MAN20001654
Version
04/24
Language
Size
6,0 MB
Doc. no. MAN20001654
操作説明書 トランスポンダー コーデッド安全スイッチ ガードロック付き CTP-L1/2-BR ユニコード/マルチコード V1.4.X ~ V1.5.X, CTA-L1/2-BR ユニコード/マルチコード V2.2.X ~ V2.3.X
Doc. no.
MAN20001654
Version
04/24
Language
Size
6,4 MB
Doc. no. MAN20001654
Návod k použití Bezpečnostní spínač s kódovaným transpondérem a jištěním ochranného krytu CTP-L1/2-BR Unicode/Multicode V1.4.X až V1.5.X, CTA-L1/2-BR Unicode/Multicode V2.2.X až V2.3.X
Doc. no.
MAN20001654
Version
04/24
Language
Size
6,4 MB

Other Documents

Ordering data

Ordernumber 168052
Item designation CTP-L1-BR-M-HA-AE-SAB-168052
Gross weight 0,kg
ECLASS 27-27-24-05 Sicherheitsgerichteter Transponderschalter mit Zuhaltung