MGB2-L1HE-MLI-U-CC-L-172787 (Order no. 172787)

Locking set MGB2-L1... (cover for indicators, key-operated rotary switch, closed-circuit current principle, door hinge on left)

  • Guard locking with guard lock monitoring
  • White signal indicator
  • Key-operated rotary switch, 1x40°, form V, spring return
  • Door hinge left
  • Lockable from the inside
  • With escape release
  • Unicode
  • For connection to any bus module MBM
  • Remote or direct mounting of bus module MBM
MGB2-L1HE-MLI-U-CC-L-172787 (Order no. 172787)

Description

Guard locking type

MGB2-L1...

Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (closed-circuit current principle)

Flexible connection to any bus module MBM

The locking set can be connected to any bus module MBM, making it the ideal choice for supplementing or expanding existing systems.

Remote mounting

If space is limited, the bus module can be remotely mounted on the locking set.

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Technical data

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-02_

Escape release MGB-E-A-100465 (Order no. 100465)

Escape release MGB-E-A-100465  (Order no. 100465)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -30 ... 55 °C
Material
Housing Die-cast zinc/stainless steel, powder-coated

Miscellaneous

Product version number V2.0.0

Handle modules MGB2-H-BA1A8-L-157022 (Order no. 157022)

Handle modules MGB2-H-BA1A8-L-157022  (Order no. 157022)

Mechanical values and environment

Installation orientation Door hinge DIN left
Degree of protection IP65
Ambient temperature -30 ... 55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Additional feature
with automatic lockout mechanism
Can be locked using escape release

Locking modules MGB2-L1-MLI-U-YM6M7-CC-L-172790 (Order no. 172790)

Locking modules MGB2-L1-MLI-U-YM6M7-CC-L-172790  (Order no. 172790)

Mechanical values and environment

Installation orientation Door hinge DIN left

Modules MGB2-L1-MLI-U-Y0000-BJ-136776

Modules MGB2-L1-MLI-U-Y0000-BJ-136776

Electrical connection values

Rated insulation voltage Ui 75 V
Rated impulse voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 350 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Storage temperature -30 ... 70 °C
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.2 x 10⁶
in case of use as door stop, and 2 Joule impact energy 0.1 x 10⁶
Total 1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (In the closed state when the connection cables, connecting cables and submodules are correctly mounted.)
Ambient temperature
at UB = 24 V DC -30 ... 55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Control of guard lockingPL e32.62x10-9420 y
Monitoring of the guard positionPL e32.62x10-9420 y
Monitoring of guard lockingPL e32.62x10-9420 y
Evaluating safety signalsPL e32.62x10-9420 y
Applies to all safety functions contained in submodules such as EMERGENCY STOP, enabling switch, etc.


Miscellaneous

Slotkonfiguration 1,1

Connection accessories AC-MC-SB-M-A-157024

Connection accessories AC-MC-SB-M-A-157024

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Storage temperature -30 ... 70 °C
Ambient temperature -30 ... 55 °C
Connection 1
Connection type 2x M4 screws
Connection type Male plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Connection accessories AC-MC-SB-F-A-157028

Connection accessories AC-MC-SB-F-A-157028

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Storage temperature -30 ... 70 °C
Ambient temperature -30 ... 55 °C
Connection 1
Connection type 2x M4 screws
Connection type Female plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Female plug
Type specification M12 EN 61076-2-101
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Accessories

Downloads

Single Documents

Other Documents

Ordering data

Ordernumber 172787
Item designation MGB2-L1HE-MLI-U-CC-L-172787
Gross weight 3,47kg
Customs tariff number 85371098
ECLASS 27-27-24-05 Sicherheitsgerichteter Transponderschalter mit Zuhaltung