Bus module MGB-B...-PN... with 3 controls/indicators, push-pull plug, Test Neuer
- 1 illuminated pushbuttons
- 1 signal indicator
- 1 operating mode selector
- including adhesive labels
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Push-pull plug
- Test New
- next test approved?
- next test two approved?
- next test three approved?
- last test?

Description
Profinet connection
Connection via push-pull plugs according to IEC 61076-3-117
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
TEST Typical operating distances
With actuators CES-A-BBA and CES-A-BCA
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.
With actuator CES-A-BPA
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Attention:
The actuating range may vary depending on the actuator, substrate material and installation situation. Further actuating ranges can be found in the operating instructions.

Dimensional drawings

Technical data
Approvals



Operating and display elements
| Occupancy diagram | B2 |
| Item | Color | Extras | Note slide-in label | Slide-in label | Version | Switching element | Number | Designation1 | LED |
|---|---|---|---|---|---|---|---|---|---|
| 11 | red | Signal indicator | |||||||
| 12 | white | Illuminated pushbutton | 1NO | ||||||
| 13 | Entsichert / Unsecured ; Sonderfunktion / Special function ; Gesichert Zentral / Secured Central | Operating mode selector | Code 2 of 3 |
Electrical connection values
| Connecting cable | |
| Ethernet | Profinet I/O cable, at least cat. 5e |
| Rated insulation voltage Ui | 75 V |
| Rated impulse voltage Uimp | 0.5 kV |
| EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
| maximum feed-in current in the connection block | |
| X1, X2 | max. 4000 mA |
| Safety class | III |
| Current consumption | max. 500 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Power supply X1 | |
| Fuse | |
| external | min. 1 A slow blow |
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
| Power supply X2 | |
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
| Connection type | |
| Push-pull power (X2 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | |
| according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X4 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) |
| Push-pull power (X1 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | |
| according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X3 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) |
| Installation orientation | any |
| Storage temperature | -25 ... 70 °C |
| Response time | |
| Operating mode selector | max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP54 |
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 55 °C |
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| Diagnostic Coverage (DC) | 99 % |
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Safe operating mode selector switch | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Miscellaneous
| Slide-in label | ||||||||||||||||
| ||||||||||||||||
| Product version number | V3.23.3 | |||||||||||||||
Interface
| Bus data protocol | Profinet (IEC 61158 type 10) |
| Safety data protocol | Profisafe (IEC 61784-3-3) |
Downloads
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2123624
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001506
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
2114575
Version
03/24
Language
Size
3,4 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ A
Doc. no.
2114575
Version
03/24
Language
Size
3,4 MB
Other Documents
Approvals and certificates
ProfiNET
Doc. no.
Version
Language
Size
ProfiNET
Doc. no.
Version
Language
Size
0,1 MB
TUEV Süd München
Doc. no.
Version
Language
Size
TUEV Süd München
Doc. no.
Version
Language
Size
0,4 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
Ordering data
| Ordernumber | 176258 |
| Item designation | MGBS-P-L1-AP-U-R-AZE-SAA-176258 |
| Gross weight | 0,kg |
| ECLASS | 27-24-26-07 Feldbus, Dez. Peripherie - Grundgerät |