HomeProdukteMultifunctional Gate Box MGBMGB-APMGBS-P-L1-AP-U-R-AZE-SAA-176258

MGBS-P-L1-AP-U-R-AZE-SAA-176258 (Order no. 176258)

Bus module MGB-B...-PN... with 3 controls/indicators, push-pull plug, Test Neuer

  • 1 illuminated pushbuttons
  • 1 signal indicator
  • 1 operating mode selector
  • including adhesive labels
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
  • Push-pull plug
  • Test New
  • next test approved?
  • next test two approved?
  • next test three approved?
  • last test?
MGBS-P-L1-AP-U-R-AZE-SAA-176258 (Order no. 176258)

Description

Profinet connection

Connection via push-pull plugs according to IEC 61076-3-117

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

TEST Typical operating distances

With actuators CES-A-BBA and CES-A-BCA

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.

With actuator CES-A-BPA

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Attention:

The actuating range may vary depending on the actuator, substrate material and installation situation. Further actuating ranges can be found in the operating instructions.

Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Technical data

Approvals

c_UL_us_E155795_3/9ProfiNET_Z10142_Version 2023TUEV Süd München_Z10 040393 0033 Rev. 01

Operating and display elements

Occupancy diagram B2
ItemColorExtrasNote slide-in labelSlide-in labelVersionSwitching elementNumberDesignation1LED
11redSignal indicator
12whiteIlluminated pushbutton1NO
13Entsichert / Unsecured ; Sonderfunktion / Special function ; Gesichert Zentral / Secured CentralOperating mode selectorCode 2 of 3

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
Push-pull power (X2 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.))
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X4 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.))
Push-pull power (X1 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.))
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X3 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.))
Installation orientation any
Storage temperature -25 ... 70 °C
Response time
Operating mode selector max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
at UB = 24 V DC -20 ... 55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Diagnostic Coverage (DC) 99 %
PLMaximum SILPFHDCategoryMission time
Safe operating mode selector switchPL e34.1x10-8420 y


Miscellaneous

Slide-in label
NumberLabelingNote
Line Secured
Quittieren
Anlage Gesichert
Line Reset
Product version number V3.23.3

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)

Downloads

Single Documents

Other Documents

Ordering data

Ordernumber 176258
Item designation MGBS-P-L1-AP-U-R-AZE-SAA-176258
Gross weight 0,kg
ECLASS 27-24-26-07 Feldbus, Dez. Peripherie - Grundgerät