LCA-4TR-50-1510-AP-156581 (Order no. 156581)

Light curtain LCA-4TR-50-1510

  • Resolution 50 mm
  • Protective field height 1510 mm
  • Extended range 20 m
  • LED indicator for weak signal
  • With plug connector M12
  • 2 safety outputs (OSSD)
  • Installation material is included with the product
LCA-4TR-50-1510-AP-156581 (Order no. 156581)

Description

Protective function

Body protection (arms/legs)

LED function display

Transmitter

Receiver

LED OK

Normal operation

LED ERROR

Fault state

LED STOP

Stop state

LED TEST

Test function

LED START

Start/restart

LED SIGNAL LOW

Weak signal

Connector assignment, transmitter

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

124 V DCOperating voltage, 24 V DCBN
2RANGE 0Device configuration, corresponds to the standard EN 61131-2WH
30 V DCOperating voltage, 0 V DCBU
4RANGE 1Device configuration, corresponds to the standard EN 61131-2BK
5FEFunctional earth (must be connected to meet the EMC requirements)GY

Connector assignment, receiver

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1FO1ASafety output, channel 1WH
224 V DCOperating voltage, 24 V DCBN
3FO1BSafety output, channel 2GN
4K1_K2/RESTARTFeedback external contactorsYE
5SEL_ADevice configurationGY
6SEL_BDevice configurationPK
70 V DCOperating voltage, 0 V DCBU
8FEFunctional earth (must be connected to meet the EMC requirements)RD
Dimension drawing<br>Wiring diagram
Dimension drawing
Wiring diagram
Dimension drawing
Dimension drawing
Wiring diagram<br>Wiring diagram receiver
Wiring diagram
Wiring diagram receiver
Wiring diagram<br>Wiring diagram transmitter
Wiring diagram
Wiring diagram transmitter
Light grids and light curtains

Dimensional drawings

Dimensional drawings
1Flat washer
2Spring washer
3Nut
AFastening bracket
BMounting plate

Dimensional drawings

Dimensional drawings
A = Height of the sensor (see technical data)

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

TÜV SÜD München_LCA4_Z10 040393 0045 Rev 00c_UL_us_E492607

Operating and display elements

LED display Yes (Self-diagnostics and status)

Electrical connection values

Receiver power consumption 2 W
Transmitter power consumption 1 W
Output current
per safety output max. 400 mA
Operating voltage DC 24 V DC -20% ... +20%
Cascadable No
Muting possible in combination with external sensors and an evaluation unit

Mechanical values and environment

Dimensions 28x30 mm (in cross-section)
Connection type Plug connector M12 (5-pin transmitter/8-pin receiver)
Number of safety outputs 2 static, self-monitoring PNP safety outputs (with short-circuit and overload protection)
Resolution 50 mm
Installation orientation any
Height of the protective field 1510 mm
Height of the sensor 1563 mm
Storage temperature -30 ... 70 °C
maximum length of connecting cables 100 m
Response time 7 ms
Range of the protective field 20000 mm
Degree of protection IP65/IP67
Ambient temperature -30 ... 55 °C

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the protective fieldPL e31.51x10-8420 y


Miscellaneous

ESPE type 4 (according to EN 61496-1)

Accessories

Downloads

Single Documents

Other Documents

Ordering data

Ordernumber 156581
Item designation LCA-4TR-50-1510-AP-156581
Gross weight 4,707kg
Customs tariff number 85365019000
ECLASS 27-27-09-10 Lichtvorhang