CMS-E-FR (Order no. 099258)

Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected

  • Up to 6 read heads can be connected
  • 2 safety contacts
  • 1 auxiliary contact
  • 6 monitoring outputs
  • 1 feedback loop can be connected
  • Start automatic/monitored/not monitored
CMS-E-FR (Order no. 099258)

Description

Functional description

The evaluation unit CMS-E-FR is suitable for the direct connection of up to 6 read heads.

Category/PL according to EN ISO 13849-1

  • Category 4/PL e with only one read head connected
  • Max. category 3/PL d with more than one read head connected

Notice:

At low approach speeds in the z direction, the time between the switching of the reed contacts must not be more than 0.6 ms.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
CMS: Magnetically coded safety switches

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Accessories

Downloads

Single Documents

Other Documents

Ordering data

Ordernumber 099258
Item designation CMS-E-FR
Gross weight 0,349kg
Customs tariff number 85364110
ECLASS 27-27-24-02 Sicherheitsgerichteter magnetischer Näherungsschalter