Locking module MGB2-L1-BP... (module without blanking covers, closed-circuit current principle)
- Locking module MGB2 for direct connection to a control system
- Configurable as interlocking or guard locking
- Category 4/PL e for the evaluation of all safety functions
- Unicode
- Open version (without blanking covers)
- Adjustable door hinge
- Test

Description
Guard locking type
MGB2-L1... | Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (closed-circuit current principle) |
Door hinge
On the locking modules, the door stop can be changed from right to left and vice versa at any time with little effort.
New test function
new text update 2026.1
Flexible adaptation through configuration
- The evaluation module can be configured with the aid of DIP switches. Depending on the setting, the evaluation module behaves like an MGB2-BP or an MGB2-BR device.
- In addition, guard lock monitoring can be switched on or off on devices with guard locking. When guard lock monitoring is switched on, the safe outputs are switched on if the guard is safely locked. When guard lock monitoring is switched off, the safe outputs are switched on if the guard is closed and the bolt tongue is inserted into the MGB2.
- Release monitoring can be activated when guard lock monitoring is switched on. This signals whether the auxiliary release or escape release was actuated.
- Factor reset permits resetting to the factory setting.


Dimensional drawings

Dimensional drawings

Technical data
Approvals


Electrical connection values
| Connection cross section | |
| (rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
| (rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
| (rigid/flexible) | 0.25 ... 1.5 mm² ((AWG 23 ... AWG 16)) |
| Rated insulation voltage Ui | 75 V |
| Rated impulse voltage Uimp | 1.5 kV |
| Discrepancy time | |
| between FO1A and FO1B | max. 999 ms |
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
| Risk time according to EN 60947-5-3 | max. 999 ms (In a series connection, the risk time increases by 10 ms for each additional device.) |
| Safety class | III |
| Transponder coding | Unicode |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring outputs OD, OT/C, OI | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
| Output current | max. 50 mA |
| Safety outputs FO1A, FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| UFO1A /UFO1B LOW | 0 ... 1 V DC |
| UFO1A /UFO1B HIGH | UB-3,5 ... UB V DC (Value at a switching current of 150mA without taking into account the cable lengths) |
| Output current | |
| per safety output FO1A / FO1B | 1 ... 150 mA |
| Turn-on time | max. 80 ms |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | min. 100 ms |
| Power supply UB | |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +20% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
| Current consumption | |
| IUB | max. 80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs) |
Mechanical values and environment
| Connection type | |
| Addition | 999 Text (Footnote) |
| Ready delay | 5 s |
| Storage temperature | -30 ... 70 °C |
| Mechanical life | |
| Total | 1 x 10⁶ |
| in case of use as door stop, and 2 Joule impact energy | 0.1 x 10⁶ |
| in case of use as door stop, and 1 Joule impact energy | 0.2 x 10⁶ |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | |
| IP65 (In the closed state when the connection cables, connecting cables and submodules are correctly mounted.) | |
| Addition | 9 ... 999 ... 999 IP65/IP67/IP69 (Footnote) |
| Ambient temperature | |
| at UB = 24 V DC | -30 ... 55 °C |
| Material | |
| Housing | Fiber glass reinforced plastic; die-cast zinc, nickel plated |
| Locking force FZh | 999 ... 999 N |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Control of guard locking | PL a | 1 | 1 | 20 y | |
| Monitoring of the guard position | PL e | 3 | 2.95x10-9 | 4 | 20 y |
Miscellaneous
| Slotkonfiguration | 1 |
Downloads
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2500504
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001507
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB2-I-BP.-… / MGB2-I-BR.-…
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB2-I-BP.-… / MGB2-I-BR.-…
Doc. no.
2530674
Version
02/23
Language
Size
4,8 MB
Mode d’emploi Systèmes de sécurité MGB2-I-BP.-… / MGB2-I-BR.-…
Doc. no.
2530674
Version
02/23
Language
Size
4,8 MB
Betriebsanleitung Sicherheitssysteme MGB2-I-BP.-… / MGB2-I-BR.-…
Doc. no.
2530674
Version
02/23
Language
Size
4,8 MB
Návod k použití Bezpečnostní systémy MGB2-I-BP.-… / MGB2-I-BR.-…
Doc. no.
2530674
Version
02/23
Language
Size
5,2 MB
Test Update 2026.1 neue Version
Doc. no.
Version
Language
Size
Test Update 2026.1 neue Version
Doc. no.
MAN20001829
Version
Language
Size
0,0 MB
Other Documents
Approvals and certificates
Asi_137501_CES FD ASi
Doc. no.
Version
Language
Size
Asi_137501_CES FD ASi
Doc. no.
20001748
Version
Language
Size
0,2 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
Ordering data
| Ordernumber | 177229 |
| Item designation | MGB2-L1HEB-PN-U-S2-CA-L-177229 |
| Gross weight | 0,kg |