HomeProdukteTransponder-coded safety switches without guard lockingCES-AP safety switchCES-I-AP-M-C04-USB-117324
Safety switch CES-I-AP-.-C04-..., RFID, plug connector(s) M12
- Multicode
- Monitoring output door position OD
- Connecting cable PUR, 0.2 m, plug connector M12, 5-core

Description
Typical operating distance
(Only in conjunction with actuator CES-A-BBN-C04)
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Attention:
The actuating range may vary depending on the actuator, substrate material and installation situation. Further actuating ranges can be found in the operating instructions.
Safety characteristics
Thanks to two redundant safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:
- Category 4 /PL e according to EN 13849-1
- SIL 3 according to EN IEC 62061 Table 4
The OSSD outputs used check their function for short circuits and short circuits with test pulses.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
Accessories required
Actuator is not included.
Dimensional drawings

| 1 | Active face |
| 2 | LED status indication |
| 3 | With rubber support |
Connection examples

Technical data
Approvals



Workspace
| Repeat accuracy R | |
| according to EN 60947-5-2 | 10 % |
Electrical connection values
| Fuse | |
| external (operating voltage) | 0.25 ... 8 A |
| Rated insulation voltage Ui | 30 V |
| Rated impulse voltage Uimp | 0.5 kV |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the outputs.) |
| Turn-on time | |
| Safety outputs | max. 300 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Risk time according to EN 60947-5-3 | max. 260 ms |
| Safety class | III |
| Current consumption | |
| no load on outputs | max. 35 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output OD | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8 x UB ... UB V DC |
| Switching current | max. 50 mA |
| Safety outputs FO1A/FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
| rated conditional short-circuit current | 100 A |
| Discrepancy time | max. 10 ms |
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
| Off-state current Ir | max. 0.25 mA |
| Switching current | |
| per safety output | 1 ... 150 mA |
| Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
| Test pulse interval | min. 100 ms |
Mechanical values and environment
| Connection type | PUR cable, 200 mm, with plug connector M12x1, 5-pin |
| Tightening torque | |
| Fixing screws | max. 0.8 Nm |
| Ready delay | 0.5 s |
| Dynamic bending radius | 10 x cable diameter |
| Static bending radius | 5 x cable diameter |
| Installation orientation | any |
| Switching frequency | max. 1 Hz |
| Storage temperature | -25 ... 70 °C |
| Mounting distance | |
| between switches | min. 80 mm |
| Mounting type | Surface mounting on metal |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP67 |
| Cable ambient temperature (dynamic) | -25 ... 65 °C |
| Cable ambient temperature (static) | -25 ... 65 °C |
| Material | |
| Rubber support | NBR 80 ±5 Shore |
| Housing | Plastic, PBT |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | - | 4.1x10-9 | 4 | 20 y |
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures |
| Additional feature | Rubber support included |
In combination with actuator CES-A-BDN-06-161742
| Switch-on distance | |
| Installation position A | 25 mm |
| Installation position C | 20 mm |
| Secured switch-off distance sar | |
| Installation position A | max. 77 mm |
| Installation position C | max. 72 mm |
| Secured switching distance sao | |
| Installation position C | min. 10 mm |
| Installation position A | min. 15 mm |
| Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BDN-06-104730
| Switch-on distance | |
| Installation position C or D (broad side) | 15 mm |
| Installation position A or B (front side) | 19 mm |
| Secured switch-off distance sar | |
| in x/z direction | max. 40 mm |
| in y direction | max. 60 mm |
| Secured switching distance sao | |
| Installation position A or B (front side) | min. 14 mm |
| Installation position C or D (broad side) | min. 10 mm |
| Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527
| Switch-on distance | |
| Installation position A or B (front side) | 15 mm |
| Installation position C or D (broad side) | 11 mm |
| Secured switch-off distance sar | |
| in x/z direction | max. 40 mm |
| in y direction | max. 60 mm |
| Secured switching distance sao | |
| Installation position C or D (broad side) | min. 6 mm |
| Installation position A or B (front side) | min. 10 mm |
| Switching hysteresis | 1 ... 2 mm |
In combination with actuator CES-A-BBN-161502
| Switch-on distance | |
| Installation position C + D | 20 mm |
| Installation position A + B | 25 mm |
| Secured switch-off distance sar | |
| in x/z direction / installation position A + B | max. 69 mm |
| in y direction / installation position A + B | max. 77 mm |
| in y direction / installation position C + D | max. 72 mm |
| in x-/z direction / installation position C + D | max. 64 mm |
| Secured switching distance sao | |
| in z direction / installation position A + B | min. 15 mm |
| in x direction/installation position C + D | min. 10 mm |
| Switching hysteresis | |
| in x direction/installation position C + D | 1 ... 2 mm |
| in z direction / installation position A + B | 1 ... 2 mm |
Accessories
Actuator
Actuator CES-A-BBN-C04

115271
CES-A-BBN-C04-115271
CES-A-BBN-C04-115271
- Cube-shaped design 42 x 25 mm
- Two safety screws M4x20 and rubber support included

161502
CES-A-BBN-161502
CES-A-BBN-161502
- Cube-shaped design 42 x 25 mm, height 12 mm
- Transponder with large actuating range
- Mounting compatible with actuators: CES-A-BBA-071840, CES-BBN-106600, CES-A-BBN-C04-115271
- Two safety screws M4x14 included
CEM-C60
Connection material
M12 extension PUR, 5-pin, plug connectors at both ends, 10 m

115565
C-M12F05-05X025PU10,0-M12M05-115565
C-M12F05-05X025PU10,0-M12M05-115565
- M12 female plug, 5-pin (angled) to M12 plug connector (straight)
- plug connectors at both ends
- PUR cable
- Cable length 10 m
- with cable exit A (right)

115566
C-M12F05-05X025PU10,0-M12M05-115566
C-M12F05-05X025PU10,0-M12M05-115566
- M12 female plug, 5-pin (angled) to M12 plug connector (straight)
- plug connectors at both ends
- PUR cable
- Cable length 10 m
- with cable exit C (left)
Downloads
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2138020
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001471
Version
Language
Size
0,2 MB
Instructions
Operating Instructions Non-Contact Safety Switch CES-I-AP-.-C04/C14-… (Unicode/Multicode)
Doc. no.
Version
Language
Size
Operating Instructions Non-Contact Safety Switch CES-I-AP-.-C04/C14-… (Unicode/Multicode)
Doc. no.
2115159
Version
05/25
Language
Size
1,7 MB
Mode d’emploi Interrupteur de sécurité sans contact CES-I-AP-.-C04/C14-… (unicode / multicode)
Doc. no.
2115159
Version
05/25
Language
Size
1,7 MB
Manual de instrucciones Interruptor de seguridad sin contacto CES-I-AP-.-C04/C14-… (Unicode/Multicode)
Doc. no.
2115159
Version
05/25
Language
Size
1,7 MB
Betriebsanleitung Berührungsloser Sicherheitsschalter CES-I-AP-.-C04/C14-… (Uni-/Multicode)
Doc. no.
2115159
Version
05/25
Language
Size
1,7 MB
Istruzioni di impiego Finecorsa di sicurezza senza contatto CES-I-AP-.-C04/C14-… (Unicode/Multicode)
Doc. no.
2115159
Version
05/25
Language
Size
1,7 MB
Návod k použití Bezkontaktní bezpečnostní spínač CES-I-AP-.-C04/C14-… (Unicode/Multicode)
Doc. no.
2115159
Version
05/25
Language
Size
2,1 MB
Other Documents
Approvals and certificates
ECOLAB
Doc. no.
Version
Language
Size
ECOLAB
Doc. no.
Version
Language
Size
0,5 MB
UQS CES-I-AP-.-C04…
Doc. no.
Version
Language
Size
UQS CES-I-AP-.-C04…
Doc. no.
ECO2116783
Version
Language
Size
0,2 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,3 MB
Sales documents
Flexibel sicher - Transpondercodierte Sicherheitssysteme CES
Doc. no.
Version
Language
Size
Flexibel sicher - Transpondercodierte Sicherheitssysteme CES
Doc. no.
119922
Version
06-06/22
Language
Size
8,4 MB
Flexibly safe - Transponder-coded safety systems CES
Doc. no.
Version
Language
Size
Flexibly safe - Transponder-coded safety systems CES
Doc. no.
120233
Version
06-06/22
Language
Size
7,3 MB
Ordering data
| Ordernumber | 117324 |
| Item designation | CES-I-AP-M-C04-USB-117324 |
| Gross weight | 0,085kg |
| Customs tariff number | 85365019000 |
| ECLASS | 27-27-24-03 Sicherheitsgerichteter Transponderschalter |